Abstract
Ultraviolet Radiation Decontamination is a non-contact decontamination method that emerges as a viable alternative, as it achieves rapid y efficient inactivation of viruses y bacteria, according to studies showing up to 90% deactivation of these microorganisms. When bacteria, protozoa, y viruses are exposed to ultraviolet light, they lose their ability to reproduce, unlike chemical methods used for disinfecting water, food, surfaces, or surgical items. Essentially, UV light denatures the DNA y RNA that make up the virus, disabling its replication capability. This document provides a literature review on the basics of disinfection systems using ultraviolet (UV) light. It also compares this system with other non-contact disinfection methods, such as the hydrogen peroxide vapor system, revealing that UV disinfection systems have fewer disadvantages. However, it is important to highlight that UV disinfection systems should be used without the presence of people or with personnel wearing safety garments, as UV-C radiation has harmful effects on health with direct exposure. According to the National Toxicology Program, this type of radiation is classified as a probable human carcinogen.
References
Andrés, A. de, Prieto de Castro, C. y Usera, F. (2020) ‘Informe sobre utilización de la radiación ultravioleta (UVC) para desinfección’. Disponible en: https://digital.csic.es/handle/10261/216311 (Accessed: 28 December 2021).
Aoyagi, Y. et al. (2011) ‘Inactivation of Bacterial Viruses in Water Using Deep Ultraviolet Semiconductor Light-Emitting Diode’, Journal of Environmental Engineering, 137(12), pp. 1215–1218. doi:10.1061/(ASCE)EE.1943-7870.0000442.
Bentancor, M. y Vidal, S. (2018) ‘Programmable y low-cost ultraviolet room disinfection device’, HardwareX, 4, p. e00046. doi:10.1016/j.ohx.2018.e00046.
Bohrerova, Z. et al. (2008) ‘Comparative disinfection efficiency of pulsed y continuous-wave UV irradiation technologies’, Water Research, 42(12), pp. 2975–2982. doi:10.1016/j.watres.2008.04.001.
Burgener, J. (2006) ‘Position Paper on the Use of Ultraviolet Lights in Biological Safety Cabinets’, Applied Biosafety, 11(4), pp. 228–230. doi:10.1177/153567600601100413.
Correa, M. et al. (2020) ‘Desinfección mediante el uso de luz UV-C germicida en diferentes medios como estrategia preventiva ante la COVID-19’, Minerva, 1(2), pp. 46–53. doi:10.47460/minerva.v1i2.11.
Luis Rossel. (2020) ‘Radiation ultraviolet-c for bacterial disinfection (total y thermotolerant coliforms) in the water treatment’, http://www.scielo.org.pe/scielo.php?script=sci_arttext&pid=S2313-29572020000100068.
Elio Pietrobon Tarrán (2002) ‘Desinfección por luz ultravioleta’, Revista Agua Latinoamerica. Disponible en: https://acortar.link/AnCmLe
Gillespie, J.B. et al. (2017) ‘Efficacy of Pulsed 405-nm Light-Emitting Diodes for Antimicrobial Photodynamic Inactivation: Effects of Intensity, Frequency, y Duty Cycle’, Photomedicine y Laser Surgery, 35(3), pp. 150–156. doi:10.1089/pho.2016.4179.
Green, C. et al. (2017) ‘Pulsed-xenon ultraviolet light disinfection in a burn unit: Impact on environmental bioburden, multidrug-resistant organism acquisition y healthcare associated infections’, Burns, 43(2), pp. 388–396. doi:10.1016/j.burns.2016.08.027.
Shelly Miller, Mark Hernandez, Kevin Fernelly, John Martyny, Janet Macher, Elmira Kujundzic, Peng Xu, Patricia Fabian, Jordan Peccia, Cody Howard (2002) EFFICACY OF ULTRAVIOLET IRRADIATION IN CONTROLLING THE SPREAD OF TUBERCULOSIS, NIOSHTIC-2. Available at: https://www.cdc.gov/niosh/nioshtic-2/20022472.html.
Kheyrandish, A., Mohseni, M. y Taghipour, F. (2017) ‘Development of a method for the characterization y operation of UV-LED for water treatment’, Water Research, 122, pp. 570–579. doi:10.1016/j.watres.2017.06.015.
Kim, D.K., Kim, S.J. y Kang, D.H. (2017) ‘Inactivation modeling of human enteric virus surrogates, MS2, Qβ, y ΦX174, in water using UVC-LEDs, a novel disinfecting system’, Food Research International, 91, pp. 115–123. doi:10.1016/j.foodres.2016.11.042.
Kim, S.-J., Kim, D.-K. y Kang, D.-H. (2016) ‘Using UVC Light-Emitting Diodes at Wavelengths of 266 to 279 Nanometers To Inactivate Foodborne Pathogens y Pasteurize Sliced Cheese’, Applied y Environmental Microbiology. Edited by J.L. Schottel, 82(1), pp. 11–17. doi:10.1128/AEM.02092-15.
Knudson, L. (2013) ‘Pulsed UV light disinfection system shows promise for OR decontamination’, AORN Journal, 98(5), pp. C1–C10. doi:10.1016/s0001-2092(13)01039-9.
Li, J. et al. (2010) ‘Enhanced germicidal effects of pulsed UV-LED irradiation on biofilms’, Journal of Applied Microbiology, 109(6), pp. 2183–2190. doi:10.1111/j.1365-2672.2010.04850.x.
Memarzadeh, F., Olmsted, R.N. y Bartley, J.M. (2010) ‘Applications of ultraviolet germicidal irradiation disinfection in health care facilities: Effective adjunct, but not stand-alone technology’, American Journal of Infection Control, 38(5 SUPPL.), pp. S13–S24. doi:10.1016/j.ajic.2010.04.208.
Menéndez López, B. (2021) ‘Sobre la desinfección de superficies por radiación UVC: un análisis numérico y experimental’. Disponible en: https://repositorio.unican.es/xmlui/handle/10902/22712 (Accessed: 28 December 2021).
Napolitano, N.A., Mahapatra, T. y Tang, W. (2015) ‘The effectiveness of UV-C radiation for facility-wide environmental disinfection to reduce health care–acquired infections’, American Journal of Infection Control, 43(12), pp. 1342–1346. doi:10.1016/j.ajic.2015.07.006.
Nerandzic, M.M. et al. (2015a) ‘Evaluation of a Pulsed Xenon Ultraviolet Disinfection System for Reduction of Healthcare-Associated Pathogens in Hospital Rooms’, Infection Control & Hospital Epidemiology, 36(2), pp. 192–197. doi:10.1017/ice.2014.36.
Nerandzic, M.M. et al. (2015b) ‘Evaluation of a Pulsed Xenon Ultraviolet Disinfection System for Reduction of Healthcare-Associated Pathogens in Hospital Rooms’, Infection Control & Hospital Epidemiology, 36(2), pp. 192–197. doi:10.1017/ice.2014.36.
Nerandzic, M.M., Fisher, C.W. y Donskey, C.J. (2014) ‘Sorting through the Wealth of Options: Comparative Evaluation of Two Ultraviolet Disinfection Systems’, PLoS ONE. Edited by P. Setlow, 9(9), p. e107444. doi:10.1371/journal.pone.0107444.
Riley, R.L. y Permutt, S. (1971) ‘Room Air Disinfection by Ultraviolet Irradiation of Upper Air’, Archives of Environmental Health: An International Journal, 22(2), pp. 208–219. doi:10.1080/00039896.1971.10665834.
Rutala, W.A., Gergen, M.F. y Weber, D.J. (2010) ‘Room Decontamination with UV Radiation’, Infection Control & Hospital Epidemiology, 31(10), pp. 1025–1029. doi:10.1086/656244.
Rutala, W.A. y Weber, D.J. (2013) ‘Disinfectants used for environmental disinfection y new room decontamination technology’, American Journal of Infection Control, 41(5 SUPPL.), pp. S36–S41. doi:10.1016/j.ajic.2012.11.006.
Rutala, W.A. y Weber, D.J. (2019) ‘Best practices for disinfection of noncritical environmental surfaces y equipment in health care facilities: A bundle approach’, American Journal of Infection Control, 47, pp. A96–A105. doi:10.1016/j.ajic.2019.01.014.
Shin, J.-Y. et al. (2016) ‘Fundamental Characteristics of Deep-UV Light-Emitting Diodes y Their Application To Control Foodborne Pathogens’, Applied y Environmental Microbiology. Edited by C.A. Elkins, 82(1), pp. 2–10. doi:10.1128/AEM.01186-15.
Song, K., Taghipour, F. y Mohseni, M. (2018) ‘Microorganisms inactivation by continuous y pulsed irradiation of ultraviolet light-emitting diodes (UV-LEDs)’, Chemical Engineering Journal, 343(March), pp. 362–370. doi:10.1016/j.cej.2018.03.020.
Spencer, M. et al. (2017) ‘A model for choosing an automated ultraviolet-C disinfection system y building a case for the C-suite: Two case reports’, American Journal of Infection Control, 45(3), pp. 288–292. doi:10.1016/j.ajic.2016.11.016.
Tran, T. et al. (2014) ‘Comparison of continuous versus pulsed ultraviolet light emitting diode use for the inactivation of Bacillus globigii spores’, Water Science y Technology, 70(9), pp. 1473–1480. doi:10.2166/wst.2014.395.
Tseng, C.C. y Li, C.S. (2005) ‘Inactivation of virus-containing aerosols by ultraviolet germicidal irradiation’, Aerosol Science y Technology, 39(12), pp. 1136–1142. doi:10.1080/02786820500428575.
Wengraitis, S. et al. (2013) ‘Pulsed UV-C Disinfection of Escherichia coli With Light-Emitting Diodes, Emitted at Various Repetition Rates y Duty Cycles’, Photochemistry y Photobiology, 89(1), pp. 127–131. doi:10.1111/j.1751-1097.2012.01203.x.
Wong, T. et al. (2016) ‘Postdischarge decontamination of MRSA, VRE, y Clostridium difficile isolation rooms using 2 commercially available automated ultraviolet-C–emitting devices’, American Journal of Infection Control, 44(4), pp. 416–420. doi:10.1016/j.ajic.2015.10.016.

This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.